Nanofiltration Membrane Nanofitration System
Nanofiltration Membrane
Model: NF1/NF2-8040
The removal of color and total organic carbon (TOC) from surface water.
The removal of hardness or radium from well water.
The overall reduction of total dissolved solids (TDS).
The separation of organic from inorganic matter in specialty food and wastewater applications.
Nanofiltration Membrane
Nanofiltration refers to a specialty-membrane process that rejects dissolved solutes in the approximate size range of 1 nanometer (10 Angstroms) — hence the term “nanofiltration.”
With respect to the size and weight of solutes that nanofiltration membranes reject, NF operates in the realm between reverse osmosis (RO) and ultrafiltration (UF) : Organic molecules with molecular weights greater than 200 – 400 are rejected. Nanofiltration membranes can effectively reject, among other contaminants:
- Dissolved organics.
- Endotoxins/pyrogens.
- Insecticides/pesticides.
- Herbicides.
- Antibiotics.
- Nitrates.
- Sugars.
- Latex emulsions.
- Metal ions.
It also rejects certain soluble salts. Specifically, NF rejects dissolved salts in the range of 20 – 98 percent. Salts which have monovalent anions (e.g., sodium chloride or calcium chloride) have rejections of 20 – 80 percent, whereas salts with divalent anions (e.g., magnesium sulfate) have higher rejections of 90 – 98 percent. Transmembrane pressures are typically 50 – 225 psi (3.5 – 16 bar).
Model | Area | Average Water Permeate | Avg MgSO4 Rejection% | Avg NaCl Rejection% | Testing Pressure (MPa) |
NF1/NF2-8040 | 37 m² | 10000 GPD (38.0m³/D) | >98% | 30—60% | 0.5—0.75MPa |
NF1/NF2-4040 | 7.6 m² | 2000 GPD (7.6m³/D) | >98% | 30—60% | 0.5—0.75MPa |
Model | A (mm/in) | B (mm/in) | C (mm/in) | D (mm/in) |
NF1/NF2-8040 | 1016 /40 | 201 /7.9 | 29 /1.125 | —– |
NF1/NF2-4040 | 1016 /40 | 96 /3.8 | 19 /0.75 | 27 /1.05 |
Application
The ideal nanofiltration membrane has a very high-water permeability, but the ideal permeability of solutes might be near zero or some higher value, depending on the solute and application. For example, an application may require near-zero permeability for pesticides and 50 percent permeability for calcium ions.
Typical applications of nanofiltration membrane systems include:
- The removal of color and total organic carbon (TOC) from surface water.
- The removal of hardness or radium from well water.
- The overall reduction of total dissolved solids (TDS).
- The separation of organic from inorganic matter in specialty food and wastewater applications.
Benifits
* System operates at a low pressure, Transmembrane pressures are typically 50 – 225 psi (3.5 – 16 bar).
* The ideal nanofiltration membrane has a very high-water permeability, but the ideal permeability of solutes might be near zero or some higher value, depending on the solute and application. For example, an application may require near-zero permeability for pesticides and 50 percent permeability for calcium ions.
Packaging
Paper carton pack.
Model | Packaged size | Dry Nano Weight | Wet Nano Weight |
NF1/NF2-8040 | 1080*210*220mm | 13 kgs | 15 kgs |
NF1/NF2-4040 | 1090*110*110mm | 4 kgs | 4.5 kgs |
Our Service
We are the supplier of Nanofiltration Membrane and Nanofiltration system, we can offer according to your project requirement.
- Description:
-
Nanofiltration Membrane
Nanofiltration refers to a specialty-membrane process that rejects dissolved solutes in the approximate size range of 1 nanometer (10 Angstroms) — hence the term “nanofiltration.”
With respect to the size and weight of solutes that nanofiltration membranes reject, NF operates in the realm between reverse osmosis (RO) and ultrafiltration (UF) : Organic molecules with molecular weights greater than 200 – 400 are rejected. Nanofiltration membranes can effectively reject, among other contaminants:
- Dissolved organics.
- Endotoxins/pyrogens.
- Insecticides/pesticides.
- Herbicides.
- Antibiotics.
- Nitrates.
- Sugars.
- Latex emulsions.
- Metal ions.
It also rejects certain soluble salts. Specifically, NF rejects dissolved salts in the range of 20 – 98 percent. Salts which have monovalent anions (e.g., sodium chloride or calcium chloride) have rejections of 20 – 80 percent, whereas salts with divalent anions (e.g., magnesium sulfate) have higher rejections of 90 – 98 percent. Transmembrane pressures are typically 50 – 225 psi (3.5 – 16 bar).
Model Area Average Water Permeate Avg MgSO4 Rejection% Avg NaCl Rejection% Testing Pressure (MPa) NF1/NF2-8040 37 m² 10000 GPD (38.0m³/D) >98% 30—60% 0.5—0.75MPa NF1/NF2-4040 7.6 m² 2000 GPD (7.6m³/D) >98% 30—60% 0.5—0.75MPa Model A (mm/in) B (mm/in) C (mm/in) D (mm/in) NF1/NF2-8040 1016 /40 201 /7.9 29 /1.125 —– NF1/NF2-4040 1016 /40 96 /3.8 19 /0.75 27 /1.05 - Application
-
Application
The ideal nanofiltration membrane has a very high-water permeability, but the ideal permeability of solutes might be near zero or some higher value, depending on the solute and application. For example, an application may require near-zero permeability for pesticides and 50 percent permeability for calcium ions.
Typical applications of nanofiltration membrane systems include:
- The removal of color and total organic carbon (TOC) from surface water.
- The removal of hardness or radium from well water.
- The overall reduction of total dissolved solids (TDS).
- The separation of organic from inorganic matter in specialty food and wastewater applications.
- Benefits
-
Benifits
* System operates at a low pressure, Transmembrane pressures are typically 50 – 225 psi (3.5 – 16 bar).
* The ideal nanofiltration membrane has a very high-water permeability, but the ideal permeability of solutes might be near zero or some higher value, depending on the solute and application. For example, an application may require near-zero permeability for pesticides and 50 percent permeability for calcium ions. - Packaging
-
Packaging
Paper carton pack.
Model Packaged size Dry Nano Weight Wet Nano Weight NF1/NF2-8040 1080*210*220mm 13 kgs 15 kgs NF1/NF2-4040 1090*110*110mm 4 kgs 4.5 kgs - Our Service
-
Our Service
We are the supplier of Nanofiltration Membrane and Nanofiltration system, we can offer according to your project requirement.