Electrophoresis Painting UF Membrane
Electrophoresis painting EUF-90 Membrane Specification
PP material hollow fiber
Electrophoretic Paint Membrane
Flow rate:100L/H
Area:12㎡
Ø90×1175mm
UPVC housing
To meet the needs of closed cycle leaching recovery of electrophoretic paint. The electrophoretic paint recovery rate can be more than 98%, which can be used to clean the electrophoretic paint. Removal of impurity ions, purification of bath solution, improve coating quality
Description
Electrophoresis painting EUF-90 Membrane, to meet the needs of closed cycle leaching recovery of electrophoretic paint. The electrophoretic paint recovery rate can be more than 98%, which can be used to clean the electrophoretic paint, which can be applied to the coated product. If you do not use the ultrafiltration system, the recovery rate is only 70%-80%.
UF Treatment Process for Electrophoresis painting:
Model | NM-EUF-90 (Material: PP Polypropylene) |
Diameter of Hollow fibers | 0.3/0.4mm |
Filtration Method | Outside-in |
Effective Membrane Area | 12m² |
Design Flow rate | 60—160L/m².H |
Potting Material | Epoxy resine |
Housing Material | U-PVC |
Pore Size | 0.02—0.1micron |
Maximumu pressure | 0.2MPa |
Inlet Liquid particle size | Less than 50um |
Pore size |
0.01 um |
Max turbidity of inlet water |
≤100 NTU |
Filtration |
Cross-flow filtration filtration |
Inlet water pressure |
0.1—0.15 MPa |
Filtration Method |
Outside-in |
Design flux |
60—100L/H |
Dia I/O |
0.3/ 0.7mm |
Max pressure difference of transmembrane |
0.1 MPa |
Applicable PH range |
2- 13 |
Tolerable continuous residual chlorine |
100 PPM |
Tolerable interval residual chlorine |
200 PPM |
Backwash Interval |
Every 15-60min |
Backwash time |
30-60sec |
Backwash pressure |
0.12—0.15MPa |
Backwash flow design |
0.8T/H |
CIP Backwashing |
Every 30-90day |
CIP Chemical |
NaClO, NaOH liquid |
Electrophoresis Painting UF Membrane Application
Electrophoretic paint UF Membrane, which is widely applied in the coating process of automobile, hardware, electrical appliances, tractors, bicycles, jewelry, spectacle frames and other industrial manufacturing industries. The use of Electrophoretic UF Membrane to recover electrophoretic paint can save 30% of the amount of electrophoretic paint, that greatly reduce the discharge of painting in the production process. The electrophoretic UF Membrane can be greatly improved by improving the conductivity in the Bath tank and the quality of coating.
We can accord to clients requirement supply the completely UF System for coating.
Benifits
* System operates at a low pressure
* Removes bacteria and viruses
* Keeps essential minerals in water
* Installs quickly and easily
* Does not generate waste water
* An ultrafiltration system is eco-friendly.
Packaging
Paper carton pack.
Our Service
We are the manufacturer of UF Membrane, we can offer according to your client requirement.
According to client requirement design the UF System.
- Description
-
Description
Electrophoresis painting EUF-90 Membrane, to meet the needs of closed cycle leaching recovery of electrophoretic paint. The electrophoretic paint recovery rate can be more than 98%, which can be used to clean the electrophoretic paint, which can be applied to the coated product. If you do not use the ultrafiltration system, the recovery rate is only 70%-80%.
UF Treatment Process for Electrophoresis painting:Model NM-EUF-90 (Material: PP Polypropylene) Diameter of Hollow fibers 0.3/0.4mm Filtration Method Outside-in Effective Membrane Area 12m² Design Flow rate 60—160L/m².H Potting Material Epoxy resine Housing Material U-PVC Pore Size 0.02—0.1micron Maximumu pressure 0.2MPa Inlet Liquid particle size Less than 50um Pore size
0.01 um
Max turbidity of inlet water
≤100 NTU
Filtration
Cross-flow filtration filtration
Inlet water pressure
0.1—0.15 MPa
Filtration Method
Outside-in
Design flux
60—100L/H
Dia I/O
0.3/ 0.7mm
Max pressure difference of transmembrane
0.1 MPa
Applicable PH range
2- 13
Tolerable continuous residual chlorine
100 PPM
Tolerable interval residual chlorine
200 PPM
Backwash Interval
Every 15-60min
Backwash time
30-60sec
Backwash pressure
0.12—0.15MPa
Backwash flow design
0.8T/H
CIP Backwashing
Every 30-90day
CIP Chemical
NaClO, NaOH liquid
- Application
-
Electrophoresis Painting UF Membrane Application
Electrophoretic paint UF Membrane, which is widely applied in the coating process of automobile, hardware, electrical appliances, tractors, bicycles, jewelry, spectacle frames and other industrial manufacturing industries. The use of Electrophoretic UF Membrane to recover electrophoretic paint can save 30% of the amount of electrophoretic paint, that greatly reduce the discharge of painting in the production process. The electrophoretic UF Membrane can be greatly improved by improving the conductivity in the Bath tank and the quality of coating.
We can accord to clients requirement supply the completely UF System for coating.
- Benefits
-
Benifits
* System operates at a low pressure
* Removes bacteria and viruses
* Keeps essential minerals in water
* Installs quickly and easily
* Does not generate waste water
* An ultrafiltration system is eco-friendly. - Packaging
-
Packaging
Paper carton pack.
- Our Service
-
Our Service
We are the manufacturer of UF Membrane, we can offer according to your client requirement.
According to client requirement design the UF System. - UF Video
-