15KLPH Industrial RO System for Underground Water Filtration
- RO Salt Rejection: ≥98.5%
- Recovery Rate: 65-70%
- RO System Rated Flux: ≥15m3/h
- The Dimension of RO Plant: 5000*3000*2200mm(L*W*H) Space requirement: 4x6m
- Working temperature: 5-40 degree / PH: 6.0—8.0
- Power: AC380V/50HZ /3phase (optional)
Description
Designed to convert high TDS saline content to drinking water, these systems use high quality RO reverse osmosis brackish water desalination membranes. These systems use our proven technology to give reliable performance and meet the demanding requirements.
15000LPH Purification RO System Includes :
* Feed Water Pump
* Pretreatment Filter ( Multi-media filter and Carbon Filter and Softener with Filter Controller )
* Cartridge filter
* High pressue pump
* RO Membrane HND-BW-8040F
* Electrical Control Panel (PLC +Touch Screen)
* Conductivity Meter and Pressure Gauges, Flow Meters
* RO System Racking, PVC & Stainless Steel Pipes
15000LPH RO System Operating Limit | RO Membrane Specifications | |||
Recovery | 60—75% | Type | TFC (Thin Film Composite) | |
Operating Temperature | ≤50℃ | Material | PA (Polyamide) | |
Operating Pressure | ≤20Bar | Working pressure | 1.55MPa | |
Electrical Power | Optional | Configuration | Spiral-Wound, FRP Wrapping | |
Max. SDI (15 min) | ≤5.0 | Membrane Size | Diameter 8”x Length 40” | |
pH range | 3–10 | Effective Area | 37m² | |
Feed Max. Turbidity | ≤1.0 NTU | Design Flow rate | 1.0m³/Hour | |
Chlorine Concentration | ≤0.1pm | Rejection (%) | 98—99% |
The Water Treatment Process:
Any further information, please don’t hesitate contact with us.
Application
Designed to convert high TDS saline content to drinking water or other industry application, these systems use high quality RO reverse osmosis seawater desalination membranes. These systems use our proven technology to give reliable performance and meet the demanding requirements of the marine environment.
From Water makers to drinking water, we offer a few range of Water Desalination Reverse Osmosis Systems—-Compact water maker and Commercial water RO System.
Information requirement for quotation
Reverse osmosis is most commonly known for its use in drinking water purification or other industry application from seawater, removing the salt and other effluent materials from the water molecules.
The basic information of your project requirement for factory:
- What’s the input raw water quality ( or know the TDS value) ?
- What’s the output usage (Application for drinking or other purpose)?
- What’s the capacity per hour?
Hinada has more that 10 years experience, skilled worker and professional engineers, good reputation.
Any inquiry or questions please send to us.
Package
High TDS Desalination Equipment RO Plant will be packaged in plywood case according to requirement.
Our Service
* Hinada is the leading manufacturer of RO System water filtration.
* Supply the completely RO plant
* Installation service
* Commissioning
* After-sales service and online training service
The document we will offer with the Reverse Osmosis Plant including:
- Installation instruction
- Operation instruction
- Flow Chart
- Spare Parts list
- Factory Inspection report
- Structure drawing and Dimension drawing
- Description:
-
Description
Designed to convert high TDS saline content to drinking water, these systems use high quality RO reverse osmosis brackish water desalination membranes. These systems use our proven technology to give reliable performance and meet the demanding requirements.
15000LPH Purification RO System Includes :
* Feed Water Pump
* Pretreatment Filter ( Multi-media filter and Carbon Filter and Softener with Filter Controller )
* Cartridge filter
* High pressue pump
* RO Membrane HND-BW-8040F
* Electrical Control Panel (PLC +Touch Screen)
* Conductivity Meter and Pressure Gauges, Flow Meters
* RO System Racking, PVC & Stainless Steel Pipes15000LPH RO System Operating Limit RO Membrane Specifications Recovery 60—75% Type TFC (Thin Film Composite) Operating Temperature ≤50℃ Material PA (Polyamide) Operating Pressure ≤20Bar Working pressure 1.55MPa Electrical Power Optional Configuration Spiral-Wound, FRP Wrapping Max. SDI (15 min) ≤5.0 Membrane Size Diameter 8”x Length 40” pH range 3–10 Effective Area 37m² Feed Max. Turbidity ≤1.0 NTU Design Flow rate 1.0m³/Hour Chlorine Concentration ≤0.1pm Rejection (%) 98—99% The Water Treatment Process:
Any further information, please don’t hesitate contact with us.
- Application
-
Application
Designed to convert high TDS saline content to drinking water or other industry application, these systems use high quality RO reverse osmosis seawater desalination membranes. These systems use our proven technology to give reliable performance and meet the demanding requirements of the marine environment.
From Water makers to drinking water, we offer a few range of Water Desalination Reverse Osmosis Systems—-Compact water maker and Commercial water RO System.
- Benefits
-
Information requirement for quotation
Reverse osmosis is most commonly known for its use in drinking water purification or other industry application from seawater, removing the salt and other effluent materials from the water molecules.
The basic information of your project requirement for factory:
- What’s the input raw water quality ( or know the TDS value) ?
- What’s the output usage (Application for drinking or other purpose)?
- What’s the capacity per hour?
Hinada has more that 10 years experience, skilled worker and professional engineers, good reputation.
Any inquiry or questions please send to us. - Package
-
Package
High TDS Desalination Equipment RO Plant will be packaged in plywood case according to requirement.
- Our Service
-
Our Service
* Hinada is the leading manufacturer of RO System water filtration.
* Supply the completely RO plant
* Installation service
* Commissioning
* After-sales service and online training serviceThe document we will offer with the Reverse Osmosis Plant including:
- Installation instruction
- Operation instruction
- Flow Chart
- Spare Parts list
- Factory Inspection report
- Structure drawing and Dimension drawing
- RO System Video
-
Here we are going to give a brief introduction on how to install and test this RO System when you get it from Hinada.
First of all, prepare a good installation site(indoor space is better) for this RO System, and enough operation space.
Secondly Install the input/output pipeline, and connect the electrical cable according to our drawing.
Thirdly, test all the pumps, valves, and water level detectors manually, and check the RO module and pipeline are all in good condition and working properly.
Fourthly, Sets the sand and activated carbon filter controller backwashing once or twice every 2 days (according to the manual of the Controller valve ). The softener resin regeneration frequency needs to be calculated according to the hardness and capacity of inlet water, one or two times per day.
Fifthly, set this RO System running automatically, do maintenance, and replace the filter element regularly.
Hinada is the leading manufacturer of RO systems, any questions about your drinking water or water treatment solutions please contact us.