5000LPH UF System for Mineral Water Treatment as drinking water
This UF System with the capacity of 5000liters/hour will deliver to our Kenya customer. And it applies to surface water filtration that makes mineral water for drinking or daily use, This UF advanced technology can remove the suspended solids, bacteria and viruses in water, and make safe with good taste water for enjoy our life.
Here we are going to give a brief introduction on how to install this UF System when we got it from Hinada.
5000LPH UF System for Mineral Water Treatment as drinking water
Firstly, prepare a good installation site for UF System and Install the input, output pipeline, and electrical cable according to our drawing.
Secondly, test each pump, valve, and water level detector manual, and check the UF module and pipeline are all in good condition and working properly. Notices, during your first-time application, it should clean the activated carbon for more than 3 hours at least.
Third, set this UF System running in automatically, and the operation process set as 30 seconds for flushing, 29 minutes for working and 1 minute for backwashing
Hinada is the leading manufacturer of UF System, any questions about your drinking water or water treatment solutions please contact us